Fire & Smoke Detection

Combine smoke, heat, flame and combustion-gas sensing to improve early fire detection along critical underground infrastructure.

Real-time visibilityEdge data continuitySystem integration

Earlier warning and location of fireCombine smoke, heat, flame and combustion-gas sensing to improve early fire detection along critical underground infrastructure.

Multi-sensor confirmation to reduce nuisance alarmsConnected data supports faster, evidence-based operational decisions.

Automatic notification and event chronologyConnected data supports faster, evidence-based operational decisions.
Application overview

What this connected-mine application does

Combine smoke, heat, flame and combustion-gas sensing to improve early fire detection along critical underground infrastructure.

The practical objective is not simply to collect more data. It is to establish a trustworthy measurement chain, detect abnormal conditions, preserve the relevant operating context and route information to the team that can act on it.

Typical points monitored

  • Smoke or obscuration
  • Heat and rate-of-rise temperature
  • Carbon monoxide
  • Flame detection where suitable
  • Linear heat cable condition
  • Ventilation, belt and equipment status
Primary field devices Smoke and heat detectors; CO transmitter; Linear heat-detection cable; Flame detector for selected hazards; Fire panel or PLC gateway
Data update pattern Event-driven alarms with periodic telemetry. Critical events should be timestamped and transmitted immediately where the communications design permits.
Connectivity options Industrial Ethernet, fibre, Wi-Fi, leaky-feeder, LoRaWAN or private LTE/5G as site conditions permit.
Alarm and analytics Generate graded alarms for detector activation, rapid heat rise, CO increase, confirmed multi-sensor fire or circuit fault.
Common integration Common interfaces include dry contacts, 4–20 mA, Modbus RTU/TCP, OPC UA, EtherNet/IP, CAN/J1939, MQTT, SNMP or REST APIs where supported by the source equipment.
Data continuity Timestamp at the edge, monitor signal quality and device health, and use store-and-forward buffering so short network outages do not create silent data gaps.
Environmental design Use mine-suitable enclosures, protected cabling and glands, appropriate ingress/impact resistance, and certified equipment wherever the hazardous-area classification requires it.

How it works

A five-layer implementation pattern

Measure

Approved sensors and machine interfaces capture the required physical or operating state.

Control locally

Existing PLCs, protection and safety systems retain their required local authority.

Acquire at edge

A rugged gateway timestamps, buffers, normalises and validates incoming data.

Transmit securely

Mine communications carry telemetry and alarms with health and quality monitoring.

Visualise and integrate

Dashboards, historians and APIs support response, maintenance and reporting.

Typical deployment locations

Where the solution can be applied

  • Conveyor roadway
  • Electrical substation
  • Workshop and fuel area
  • Battery charging station and shaft station
Operational value

Potential benefits

  • Earlier warning and location of fire
  • Multi-sensor confirmation to reduce nuisance alarms
  • Automatic notification and event chronology
  • Integration with ventilation and equipment status
  • Faster maintenance of detector circuits

Engineering considerations

Design details that determine success

  • Fire system design must comply with mine requirements
  • Keep certified life-safety functions independent and fail-safe
  • Account for dust, moisture and diesel aerosols
  • Test detectors, cables, sirens and communications routinely
Safety and control boundary

Keep protection local and approved.

Generate graded alarms for detector activation, rapid heat rise, CO increase, confirmed multi-sensor fire or circuit fault. Dashboard alerts, remote notifications and analytics should complement—not replace—certified protection, local interlocks, emergency procedures, statutory inspections and competent decision-making.

Related applications

Continue exploring the connected mine

Frequently asked questions

Implementation questions

Can Fire & Smoke Detection connect to existing PLC, SCADA or mine systems?

Usually, yes. The preferred approach is to reuse approved source data and add isolated field instrumentation only where required. The final interface depends on available protocols, network segregation, data ownership and the source equipment vendor.

Does the IoT layer replace local protection or safety controls?

No. Protection relays, safety PLCs, emergency stops, gas trips, fire systems and other approved local functions remain the primary safety and control layer. IoT adds visibility, history, notifications and decision support.

What happens when underground communications are interrupted?

Critical local functions continue independently. A suitable edge gateway buffers timestamped data, raises a communications-health alarm and forwards retained records after the connection returns.

How are sensors and alarm levels selected?

Selection starts with the mine risk assessment, required decision, environmental classification, measuring range, response time, maintainability and applicable rules. Alarm and trip levels must be approved for the specific site and jurisdiction.